Fail-Safe Table
When any of the following DTCs is detected, P/S control module enters fail-safe mode as long as malfunction continues to exist. The fail-safe mode is canceled when the applicable cancel condition is satisfied.
FAIL-SAFE CHART
| DTC | Fail-safe operation | Fail-safe cancel operation |
|---|---|---|
| C1111 | P/S motor and fail-safe relay turned off. | Push engine switch to change ignition mode of keyless push start system to "OFF". |
| C1113 | ||
| C1115 | ||
| C1116 | ||
| C1122 | P/S motor turned off. | Engine speed input is more than 600 rpm or push engine switch to change ignition mode of keyless push start system to "OFF". |
| C1131 | P/S motor and fail-safe relay turned off. | Push engine switch to change ignition mode of keyless push start system to "OFF". |
| C1141 | ||
| C1142 | ||
| C1143 | ||
| C1145 | ||
| C1146 | ||
| C1152 | ||
| C1153 | P/S motor turned off. | Contact voltage of fail-safe relay is more than 10 V and lower than 17 V or push engine switch to change ignition mode of keyless push start system to "OFF". |
| C1154 | P/S motor turned off. | Contact voltage of fail-safe relay is more than 10 V or push engine switch to change ignition mode of keyless push start system to "OFF". |
| C1155 | P/S motor turned off or P/S motor and failsafe relay turned off. | Recovery or push engine switch to change ignition mode of keyless push start system to "OFF". |
| C1160 | Default assist map is applied. | Set correct assist map. |
| C1161 | Assist value is decreased to minimum. | Normal data is received or push engine switch to change ignition mode of keyless push start system to "OFF". |
| C1162 | Assist stopped. | |
| C1164 | Vehicle dynamics synthetic control is stopped. | |
| U0100 | Assist is stopped or assist value is decreased to minimum. |