Fail-Safe Table
This function is provided by the safe mechanism that assures safe driveability even when the solenoid valve, sensor or its circuit fails. The following table shows the fail-safe function for each fail condition of solenoid valve, sensor or its circuit.
DTC REFERENCE
| DTC | DTC name | Fail-safe operation |
|---|---|---|
| P0602 | Control Module Programming Error | - |
| P062F | Internal Control Module EEPROM Error | - |
| P0641 | Sensor Reference Voltage "A" Circuit/Open | - |
| P0703 | Brake Switch "B" Circuit | TCM controls actuators assuming that brake light switch is always on. |
| P0705 | Transmission Range Sensor "A" Circuit (PRNDL Input) |
|
| P0707 | Transmission Range Sensor "A" Circuit Low | |
| P0711 | Transmission Fluid Temperature Sensor "A" Circuit Range/Performance | TCM controls actuators assuming that CVT fluid temperature is specified value. |
| P0712 | Transmission Fluid Temperature Sensor "A" Circuit Low | |
| P0713 | Transmission Fluid Temperature Sensor "A" Circuit High | |
| P0716 | Input/Turbine Speed Sensor "A" Circuit Range/Performance |
|
| P0717 | Input/Turbine Speed Sensor "A" Circuit No Signal | |
| P0721 | Output Speed Sensor Circuit Range/Performance |
|
| P0722 | Output Speed Sensor Circuit No Signal | |
| P0741 | Torque Converter Clutch Circuit Performance or Stuck Off | TCM stops lock-up control operation. |
| P0776 | Pressure Control Solenoid "B" Performance/Stuck Off | - |
| P0777 | Pressure Control Solenoid "B" Stuck On | TCM transmits torque request signal to ECM (torque reduction). |
| P0826 | Up and Down Shift Switch Circuit | TCM stops manual shift mode control. |
| P0842 | Transmission Fluid Pressure Sensor/Switch "A" Circuit Low |
|
| P0843 | Transmission Fluid Pressure Sensor/Switch "A" Circuit High | |
| P0847 | Transmission Fluid Pressure Sensor/Switch "B" Circuit Low |
|
| P0848 | Transmission Fluid Pressure Sensor/Switch "B" Circuit High | |
| P0871 | Transmission Fluid Pressure Sensor/Switch "C" Circuit Range/Performance |
|
| P0961 | Pressure Control Solenoid "A" Control Circuit Range/Performance |
|
| P0962 | Pressure Control Solenoid "A" Control Circuit Low | TCM maximizes line pressure value (duty 0%). |
| P0963 | Pressure Control Solenoid "A" Control Circuit High | |
| P0966 | Pressure Control Solenoid "B" Control Circuit Low | TCM maximizes secondary pressure value (duty 0%). |
| P0967 | Pressure Control Solenoid "B" Control Circuit High | |
| P1706 | Torque Request Communication Error from TCM | - |
| P1810 | Lockup/Select Control Circuit | TCM controls actuators assuming that lock-up/select switching solenoid valve is OFF. |
| P1816 | Stepper Motor Circuit Malfunction |
|
| P1818 | Stepper Motor Performance | - |
| P1824 | External ROM No Read | TCM controls actuators assuming that secondary pressure is specified pressure. |
| P1825 | External ROM Verification Error | TCM controls actuators assuming that secondary pressure is specified pressure. |
| P1970 | Sensor Ground Circuit Malfunction |
|
| P2763 | Torque Converter Clutch Pressure Control Solenoid Control Circuit High | TCM stops lock-up operation. |
| P2764 | Torque Converter Clutch Pressure Control Solenoid Control Circuit Low | |
| U0073 | Control Module Communication Bus Off | - |
| U0100 | Lost Communication With ECM |
|
| U0121 | Lost Communication With ABS | - |
| U0140 | Lost Communication With BCM | - |