Scan Tool Data Definitions

Temp Cont Switch: (Temperature control selector position, Max Cool, °C/°F, Max Hot  ) This parameter indicates the selected position of temperature control selector.

Mode Cont Switch (Air flow selector position, AUTO, FACE, B/L, FOOT, D/F, DEF  ) This parameter indicates the selected position of air flow selector.

Fan Cont Switch (Blower speed selector, AUTO, OFF, 1st - 8th  ) This parameter indicates the selected position of blower speed selector.

Air Intake Mode (Air intake selector position, AUTO, FRE, REC  ) This parameter indicates the selected position of air intake switch.

Vehicle Speed (km/h, mph  ) This parameter indicates the vehicle speed calculated by ECM.

ECT (Engine coolant temperature °C, °F  ) This parameter indicates the engine coolant temperature measured by engine coolant temperature sensor.

Engine Type (Engine type signal, J20  ) This parameter indicates the engine type signal transmitted by ECM.

Meter Spec (Combination meter spec signal, US, CA, MX  ) This parameter indicates the combination meter spec signal transmitted by combination meter.

Outside Air Temp (Outside air temperature, °C, °F  ) This parameter indicates the outside air temperature measured by outside air temperature sensor.

Cabin Temperature (In-car temperature, °C, °F  ) This parameter indicates the in-car temperature measured by inside air temperature sensor.

Sun Load (W/m 2  ) This parameter indicates the amount of sunlight measured by sunload sensor.

Evaporator Temp (Evaporator temperature, °C, °F  ) This parameter indicates the temperature of air passed through evaporator.

Refrigerant Pressure (A/C refrigerant absolute pressure, kPa  ) This parameter indicates the A/C refrigerant absolute pressure calculated by ECM

Air Mix Pos Sen (Temperature control actuator position sensor, V  ) This parameter indicates the input signal from position sensor in temperature control actuator.

Mode Pos Sensor (Air flow control actuator position sensor, V  ) This parameter indicates the input signal from position sensor in air flow control actuator.

Fan Desired Volt (Fan desired voltage, V  ) This parameter indicates the consumption voltage of blower motor.

A/C Cont Sig (A/C control signal, ON, OFF  ) This parameter indicates the status of A/C switch.

Blower Load Sig (Blower fan load signal, ON, OFF  ) ON: Position of blower speed selector is 1st position or more.

OFF: Position of blower speed selector is OFF position.

A/C Comp Clutch (A/C compressor magnet clutch, ON, OFF  ) This parameter indicates the status of the A/C compressor magnet clutch.