As the data values given in the following table are standard values estimated on the basis of values obtained from the normally operating vehicles by using a scan tool, use them as reference values. Even when the vehicle is in good condition, there may be cases where the checked value does not fall within each specified data range. Therefore, judgment as abnormal should not be made by checking with these data alone.

Also, condition in the following table that can be checked by the scan tool are those detected by TCM and output from TCM as commands and there may be cases where the CVT or actuator is not operating (in the condition) as indicated by the scan tool.

NOTE: The following scan tool data related to CVT can be checked only by communicating with TCM.
SYMPTOM DIAGNOSIS DESCRIPTION CHART

Scan tool data Vehicle condition Normal condition/reference values
Vehicle Speed see Scan Tool Data Definitions  Vehicle: Running Value as same as speedometer reading
Engine Speed see Scan Tool Data Definitions 
  • Engine: Specified idle speed after warming up
  • Select lever: "N" range
650 RPM
Primary Pulley Speed see Scan Tool Data Definitions  Vehicle: Stop 0 RPM
Lock-up: On Value as same as engine speed
Secondary Pulley Speed see Scan Tool Data Definitions  Vehicle: Stop 0 RPM
Vehicle: Running at 40 km/h (25 mile/h) 2000 RPM
Torque converter Slip see Scan Tool Data Definitions 
  • Engine: Specified idle speed
  • Select lever: "N" range
Approx. 127 RPM
Primary Oil Pres see Scan Tool Data Definitions 
  • Engine: Specified idle speed
  • Select lever: "N" range
Approx. 1.0 MPa
Secondary Oil Pres see Scan Tool Data Definitions 
  • Engine: Specified idle speed
  • Select lever: "N" range
Approx. 1.0 MPa
CVTF Temperature see Scan Tool Data Definitions  After driving the vehicle, the temperature around CVT fluid temperature sensor reaches 70 - 80 °C (158 - 176 °F) 70 - 80 °C (158 - 176 °F)
ECT see Scan Tool Data Definitions  Engine: Specified idle speed after warming up 80 to 110 °C (176 to 230 °F)
Battery Voltage see Scan Tool Data Definitions  Engine: Specified idle speed 13 to 15 V
Throttle position see Scan Tool Data Definitions 
  • Engine: Stop
  • Accelerator pedal: Released
  • Throttle valve: Default position
0 to 5%
  • Engine: Stop
  • Accelerator pedal: Depressed fully
  • Throttle valve: Opened fully
90 to 100%
Accel Actual Position see Scan Tool Data Definitions 
  • Engine: Stop
  • Accelerator pedal: Released
0 to 10%
  • Engine: Stop
  • Accelerator pedal: Depressed fully
90 to 100%
Gear Actual Ratio see Scan Tool Data Definitions  Vehicle: Running 0.40 - 2.34
Lock Up Solenoid (Com) see Scan Tool Data Definitions 
  • Vehicle: Running
  • Lock-up: Off
Approx. 200 mA
  • Vehicle: Running
  • Lock-up: On
Approx. 500 mA
Lock Up Solenoid (Mon) see Scan Tool Data Definitions 
  • Vehicle: Running
  • Lock-up: Off
Approx. 200 mA
  • Vehicle: Running
  • Lock-up: On
Approx. 500 mA
Line Press Solenoid (Com) see Scan Tool Data Definitions 
  • Engine: Running
  • Select lever: "N" range
  • Accelerator pedal: Released (Engine: idle speed)
Approx. 700 mA
  • Engine: Running
  • Select lever: "D" or "R" range
  • Accelerator pedal: Depressed fully
Approx. 200 mA
Line Press Solenoid (Mon) see Scan Tool Data Definitions 
  • Engine: Running
  • Select lever: "N" range
  • Accelerator pedal: Released (Engine: idle speed)
Approx. 700 mA
  • Engine: Running
  • Select lever: "D" or "R" range
  • Accelerator pedal: Depressed fully
Approx. 200 mA
Secondary Solenoid (Com) see Scan Tool Data Definitions 
  • Engine: Running
  • Select lever: "N" range
  • Accelerator pedal: Released (Engine: idle speed)
Approx. 600 mA
  • Engine: Running
  • Select lever: "D" or "R" range
  • Accelerator pedal: Depressed fully
Approx. 200 mA
Secondary Solenoid (Mon) see Scan Tool Data Definitions 
  • Engine: Running
  • Select lever: "N" range
  • Accelerator pedal: Released (Engine: idle speed)
Approx. 700 mA
  • Engine: Running
  • Select lever: "D" or "R" range
  • Accelerator pedal: Depressed fully
Approx. 200 mA
Torque Converter Clutch see Scan Tool Data Definitions  Lock-up: Off Release
Lock-up: Off ↔ On Slip
Lock-up: On Connect
Manual Gear Position see Scan Tool Data Definitions  Select lever: other than "M" range deactive
  • Select lever: "M" range
  • Manual mode gear position: 1
1st
  • Select lever: "M" range
  • Manual mode gear position: 2
2nd
  • Select lever: "M" range
  • Manual mode gear position: 3
3rd
  • Select lever: "M" range
  • Manual mode gear position: 4
4th
  • Select lever: "M" range
  • Manual mode gear position: 5
5th
  • Select lever: "M" range
  • Manual mode gear position: 6
6th
Shift Down SW see Scan Tool Data Definitions  Select lever: "-" position ON
Other than above condition OFF
Shift Up SW see Scan Tool Data Definitions  Select lever: "+" position ON
Other than above condition OFF
Manual Mode SW see Scan Tool Data Definitions  Select lever: "M" range ON
Other than above condition OFF
Transaxle Range see Scan Tool Data Definitions  Select lever is in "P" position P
Select lever is in "R" position R
Select lever is in "N" position N
Select lever is in "D" position D
ABS Active see Scan Tool Data Definitions  ABS operating ON
ABS not operating OFF
A/C Comp Clutch see Scan Tool Data Definitions 
  • Engine: Running
  • A/C switch: ON
  • Blower speed selector: ON
ON
Other than above condition OFF
Brake Switch see Scan Tool Data Definitions  Brake pedal: Depressed fully ON
Brake pedal: Released OFF
Paddle Up SW see Scan Tool Data Definitions  Right side shift paddle "+": Pulled ON
Right side shift paddle "+": Released OFF
Paddle Down SW see Scan Tool Data Definitions  Left side shift paddle "-": Pulled ON
Left side shift paddle "-": Released OFF
Switching Solenoid (Mon) see Scan Tool Data Definitions  Select lever: "P" or "N" range ON
Select lever: "D" or "R" range OFF
Switching Solenoid (Com) see Scan Tool Data Definitions  Select lever: "P" or "N" range ON
Select lever: "D" or "R" range OFF