LEMON Manuals: Even more car manuals for everyone
Home >> Suzuki >> 2012 >> SX4 Base >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 1 (Continuously Variable Transaxle (CVT)) >> Diagnostic Information and Procedures >> DTC Table

DTC Table

WARNING: This page is about a different variant/trim than selected.
NOTE:
  • With the CAN communication OBD generic scan tool, DTC No. with delta (Δ) mark in the following table can not be read.
  • For details of D/C (driving cycle), refer to ON-BOARD DIAGNOSTIC SYSTEM DESCRIPTION .
SYMPTOM DIAGNOSIS DESCRIPTION CHART

DTC DTC name DTC detecting condition DTC detection logic MIL
P0602  Control Module Programming Error TCM internal failure (data programming error). 1 D/C Not applicable
P062F  Internal Control Module EEPROM Error TCM internal failure (EEPROM). 1 D/C Applicable
P0641  Sensor Reference Voltage "A" Circuit/Open Primary and secondary pressure sensor power supply circuit voltage is out of specified value for 5 sec. 1 D/C Applicable
P0703  Brake Switch "B" Circuit Brake light switch signal received from ECM is no change. 2 D/C Applicable
P0705  Transmission Range Sensor Circuit "A" (PRNDL Input) Two or more transmission range sensor signals are input simultaneously for 2 sec. 1 D/C Applicable
P0707  Transmission Range Sensor "A" Circuit Low Transmission range signal is not input for 10 sec. 2 D/C Applicable
P0711  Transmission Fluid Temperature Sensor "A" Circuit Range/Performance CVT fluid temperature variation is lower than specified value even if engine was running for specified time after engine start. 2 D/C Applicable
P0712  Transmission Fluid Temperature Sensor "A" Circuit Low CVT fluid temperature signal circuit voltage is lower than specified value for 5 sec. 1 D/C Applicable
P0713  Transmission Fluid Temperature Sensor "A" Circuit High CVT fluid temperature signal circuit voltage is higher than specified value for 5 sec. 1 D/C Applicable
P0716  Input/Turbine Speed Sensor "A" Circuit Range/Performance This DTC is detected if all the following conditions are met.
  • Difference between engine speed and primary pulley speed is more than 1000 RPM for 5 sec. when lock-up on.
  • Difference between measured value and estimated value of primary pulley speed is more than 1000 RPM for 5 sec. when lock-up ON.
2 D/C Applicable
P0717  Input/Turbine Speed Sensor "A" Circuit No Signal Primary pulley speed signal is no signal even if secondary pulley speed signal is input. 1 D/C Applicable
P0721  Output Speed Sensor Circuit Range/Performance This DTC is detected if all of the following conditions are met.
  • Difference between measured engine speed and the estimated secondary pulley speed is more than 1000 RPM for 5 sec. when lock-up ON.
  • Difference between measured primary pulley speed and the estimated secondary pulley speed is more than 1000 RPM for 5 sec. when lock-up ON.
2 D/C Applicable
P0722  Output Speed Sensor Circuit No Signal This DTC is detected if any one of the following conditions is fulfilled.
  • The secondary pulley speed is lower than 150 RPM for 5 sec. in a row when the primary pulley speed is more than 1000 RPM.
  • The secondary pulley speed is 0 RPM for specified times when the vehicle speed is more than 10 km/h (6 mile/h).
1 D/C Applicable
P0741  Torque Converter Clutch Circuit Performance or Stuck Off Difference between engine speed and primary pulley speed is more than 130 RPM for 30 sec. even if TCC solenoid valve is ON. 2 D/C Applicable
P0776  Pressure Control Solenoid "B" Performance/Stuck Off Difference between measured secondary pressure and desired secondary pressure is more than 1.2 MPa (12.2 kgf/cm2 , 174 psi, 12 bar) for 30 sec. 2 D/C Applicable
P0777  Pressure Control Solenoid "B" Stuck On Difference between measured secondary pressure and desired secondary pressure is more than specified pressure value. 2 D/C Applicable
Δ P0826  Manual mode Control Circuit This DTC is detected if any one of the following conditions is fulfilled.
  • Manual mode switch ON signal continues to be input for more than 5 sec. even after "P", "R" or "N" range signal input.
  • ON signal of shift-down switch or shift-up switch is input for more than 5 sec. even while manual mode switch is OFF.
1 D/C Not applicable
P0842  Transmission Fluid Pressure Sensor/Switch "A" Circuit Low Primary pressure sensor signal circuit voltage is lower than specified value for 5 sec. 1 D/C Applicable
P0843  Transmission Fluid Pressure Sensor/Switch "A" Circuit High Primary pressure sensor signal circuit voltage is more than 4.7 V for 5 sec. 1 D/C Applicable
P0847  Transmission Fluid Pressure Sensor/Switch "B" Circuit Low Secondary pressure sensor signal circuit voltage is lower than specified value for 5 sec. 1 D/C Applicable
P0848  Transmission Fluid Pressure Sensor/Switch "B" Circuit High Secondary pressure sensor signal circuit voltage is more than 4.7 V for 5 sec. 1 D/C Applicable
P0871  Transmission Fluid Pressure Sensor/Switch "C" Circuit Range/Performance Measured line pressure is out of specified line pressure that calculate base on secondary pressure for 5 sec. 2 D/C Applicable
P0961  Pressure Control Solenoid "A" Control Circuit Range/Performance Gear ratio calculated from primary pulley speed and secondary pulley speed is more than specified value. 2 D/C Applicable
P0962  Pressure Control Solenoid "A" Control Circuit Low Line pressure control solenoid valve control circuit is shorted to ground for specified times. 1 D/C Applicable
P0963  Pressure Control Solenoid "A" Control Circuit High Line pressure control solenoid valve control circuit is open circuit for 5 sec. 1 D/C Applicable
P0966  Pressure Control Solenoid "B" Control Circuit Low Secondary pressure control solenoid valve control circuit is shorted to ground for specified times. 1 D/C Applicable
P0967  Pressure Control Solenoid "B" Control Circuit High Secondary pressure control solenoid valve control circuit is open circuit for 5 sec. 1 D/C Applicable
Δ P1706  Torque Request Communication Error from TCM ECM detects abnormality of CAN communication data which TCM transmits. 1 D/C Not applicable
P1810  Lockup/Select Control Circuit Monitor signal of the lock-up/select switching solenoid valve is different from its command signal. 1 D/C Applicable
P1816  Stepper Motor Circuit Malfunction Monitor signal of stepper motor is different from its command signal. 1 D/C Applicable
P1818  Stepper Motor Performance Difference between measured primary pulley speed and estimated primary pulley speed is more than 1000 RPM for 5 sec. 2 D/C Applicable
P1824  Calibration Data Reading Error TCM cannot read calibration data from valve body assembly internal ROM. 1 D/C Off
P1825  TCM-Valve Body Assembly Correlation Calibration data in TCM is different from that in valve body assembly internal ROM. 2 D/C Off
P1970  Sensor Ground Circuit Malfunction Ground circuit of following sensors is open circuit for specified times.
  • CVT fluid temperature sensor
  • Primary pressure sensor
  • Secondary pressure sensor
1 D/C Applicable
P2763  Torque Converter Clutch Pressure Control Solenoid Control Circuit High TCC (Torque Converter Clutch) solenoid valve circuit is open for 5 sec. 1 D/C Applicable
P2764  Torque Converter Clutch Pressure Control Solenoid Control Circuit Low TCC (Torque Converter Clutch) solenoid valve circuit is shorted to ground for specified times. 1 D/C Applicable
U0073  Control Module Communication Bus Off Refer to TROUBLESHOOTING FOR CAN-DTC . 1 D/C Applicable
U0100  Lost Communication With ECM Transmission error that is inconsistent between transmission data and transmission monitor (CAN bus monitor) data is detected more than 30 times continuously. 1 D/C Applicable
U0121  Lost Communication With ABS Reception error of communication data for ABS/ESP® control module assembly is detected for longer than specified time. 1 D/C Applicable
Δ U0140  Lost Communication With BCM Reception error of communication data for BCM is detected for longer than specified time. 1 D/C Not applicable