Circuit/System Testing
WARNING: This page is about a different car, the 2007 Suzuki XL7. However, it is still accessible from the selected car via links, so may be relevant.
Dome Lamp Switch Circuit Testing
- Ignition OFF, disconnect the harness connector at the dome lamp switch.
- Ignition OFF, test for less than 1 Ω of resistance between the ground circuit and ground.
- If greater than 1 Ω, test the ground circuit for an open/high resistance.
- Verify the scan tool door lamp command parameter is OFF.
- If the dome lamp command is not OFF, test the signal circuit for a short to ground. If the circuit tests normal, replace the BCM.
- Install a 3-amp fused jumper wire between the voltage supply circuit and ground. Verify the Scan Tool Dome Lamp Command parameter is ON.
- If the dome lamp command is not ON, test the signal circuit of the dome lamp switch for a short to voltage or an open/high resistance. If circuit tests normal, replace the BCM.
- Install a 3-amp fused jumper wire between the voltage supply circuit and door signal circuit. Verify the Scan Tool Dome Lamp Command parameter is ON when a door is in the open position.
- If the dome lamp command is not ON, test the signal circuit of the dome lamp switch for a short to voltage or an open/high resistance. If circuit tests normal, replace the BCM.
- If all circuits test normal, test or replace the dome lamp switch.NOTE: This test can be performed on any of the door ajar switches.
Door Ajar Switch Circuit Testing
- Ignition OFF, disconnect the harness connector at the inoperative door ajar switch.
- Ignition OFF, test for less than 1 Ω of resistance between the ground circuit and ground.
- If greater than 1 Ω, test the ground circuit for an open/high resistance.
- Verify the scan tool dome lamp command parameter is OFF.
- If the dome lamp command is not OFF, test the signal circuit for a short to ground. If the circuit tests normal, replace the BCM.
- Install a 3-amp fused jumper wire between the voltage supply circuit and ground. Verify the scan tool dome lamp command parameter is ON.
- If the dome lamp is not ON, test the signal circuit of the door ajar switch for a short to voltage or an open/high resistance. If circuit tests normal, replace the BCM.
- If all circuits test normal, test or replace the door ajar switch.