LEMON Manuals: Even more car manuals for everyone
Home >> Suzuki >> 2012 >> Equator Base >> Repair and Diagnosis >> Electrical >> Charging Systems >> Diagnostic Information and Procedures >> S Terminal Circuit Check >> Description

S Terminal Circuit Check: Description

The output voltage of the generator is controlled by the IC regulator at terminal "3" (S) detecting the input voltage. Terminal "3" circuit detects the battery voltage to adjust the generator output voltage with the IC regulator.