LEMON Manuals: Even more car manuals for everyone
Home >> Suzuki >> 2011 >> Grand Vitara Base >> Repair and Diagnosis >> Engine Performance >> System >> Engine Control System Diagnosis >> General Description >> OBD System Description - Comprehensive Component (Rationality) Monitor (EVAP Leak Check Model) >> ECT Sensor Rationality Monitor

ECT Sensor Rationality Monitor

OPERATION (1 OF 3)

DTC P0116
Monitor execution Once per driving cycle
Monitoring duration Not applicable (Phase 1), 700 sec. (Phase 2)
OPERATION (2 OF 3)

DTC P0125
Monitor execution Once per driving cycle
Monitoring duration 90 - 300 sec. (according to ECT at engine start)
OPERATION (3 OF 3)

DTC P011B
Monitor execution Once per driving cycle
Monitoring duration 5 sec.
ENABLE CONDITIONS

Parameter Min. Max.
P0116 
Phase 1 
ECT - 71 °C (159 °F)
Warm up counter (according to ECT at engine start) 120 sec. -
Engine load (according to barometric pressure and engine speed) 0.112 - 0.188 (M/T), 0.135 - 0.208 (A/T)
Fuel system status Not fuel shut off
ECT sensor No DTC (P0117, P0118)
MAF sensor No DTC (P0102, P0103)
Phase 2 
ECT 70 °C (158 °F) -
ECT Sensor No DTC (P0117, P0118)
Soak Timer 1200 sec. -
IAT Change 2.5 °C (36.5 °F) -
P0125 
ECT at engine start - -5 °C (23 °F)
Engine speed 500 RPM -
Warm up counter (according to ECT at engine start) 90 - 300 sec. -
ECT sensor No DTC (P0117, P0118)
MAF sensor No DTC (P0102, P0103)
Engine load (according to barometric pressure and engine speed) 0.112 - 0.188 (M/T), 0.135 - 0.208 (A/T)
Fuel system status Not fuel shut off
P011B 
Battery voltage 11V -
Ignition switch OFF
Duration time from engine off 5 hours -
ETC drop after engine start (Block heater detection) - 2 °C (3.6 °F)
TYPICAL MALFUNCTION THRESHOLDS

P0116:  ECT sensor voltage change < 0.01465 V
P0125:  ECT < -5 °C (23 °F)
P011B: 
Phase 1:  Difference between ECT and IAT < -30 °C (-54 °F)
Phase 2B:  Difference between ECT and IAT > 30 °C (54 °F)