CMP Control System Monitor
OPERATION (1 OF 3)
| DTC | P0010 |
| Monitor execution | Not applicable |
| Monitoring duration | 5, 000 msec. |
OPERATION (2 OF 3)
| DTC | P0011, P0012 |
| Monitor execution | Not applicable |
| Monitoring duration | 2, 000 msec. - 10, 000 msec. |
OPERATION (3 OF 3)
| DTC | P0016 |
| Monitor execution | Not applicable |
| Monitoring duration | 1, 024 msec. |
ENABLE CONDITIONS
| Parameter | Min. | Max. |
|---|---|---|
| P0010 | ||
| Phase 1 | ||
| OCV duty | 30% | - |
| Phase 2 | ||
| OCV duty | - | 35% |
| P0011, P0012 | ||
| OCV | No DTC (P0010) | |
| CKP sensor | No DTC (P0335) | |
| CMP sensor | No DTC (P0340) | |
| P0016 | ||
| Target CMP control system | = 0 ° | |
TYPICAL MALFUNCTION THRESHOLDS
| P0010 | |
| Phase 1: | OCV current < 0.2 A |
| Phase 2: | OCV current > 0.8 A |
| P0011: | CMP control system target - actual < -12 ° |
| P0012: | CMP control system target - actual > 15 ° |
| P0016 | |
| Phase 1: | CKP - CMP difference at the end of last driving cycle > CKP - CMP difference +10 ° |
| Phase 2: | CKP - CMP difference at the end of last driving cycle < CKP - CMP difference -10 ° |
| Phase 3: | CKP - CMP difference < 3 ° |
| Phase 4: | CKP - CMP difference > 29 ° |