Circuit/System Testing
- Ignition OFF, remove the fuse that supplies voltage to terminals C2-3, C2-5, and C2-6 of the ECM. Verify the fuse is OK.NOTE: This DTC will only set if the fuse is open and the circuits are not grounded. The ignition voltage circuits must be tested thoroughly for an intermittent short to ground.
- If the fuse is open, test the ignition voltage circuit between the open fuse and the ECM for an intermittent short to ground.
- Install the fuse.
- Disconnect the harness connector of the ECM. Ignition ON, load test for battery voltage on the ignition circuits at the ECM.
- If less than B+, repair the ignition circuit for an open/high resistance.
- If all circuits/connections test OK, replace the ECM.