LEMON Manuals: Even more car manuals for everyone
Home >> Suzuki >> 2007 >> SX4 Base, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 235 (Engine Control System - Introduction) >> General Description >> OBD System Description - Oxygen Sensor Monitor >> Heated Oxygen Sensor Circuit No Activity Detected B1S2 & B2S2 >> Secondary Parameters And Enable Conditions

Secondary Parameters And Enable Conditions

WARNING: This page is about a different car, the 2006 Suzuki Verona. However, it is still accessible from the selected car via links, so may be relevant.

Plausibility fault:

Enable Conditions:

IGK "ON"

No O2 downstream error

200 g > Air mass flow integral during pull cut off phase > 20 g

And

MAF integral out of DFCO in case of certain load threshold exceeded ≥ 1,200 g

This diagnostic is inhibited if any of the following DTC's are present:

MAF fault

MAP fault

O2 downstream sensor fault

CPS fault

FSD fault

PS/MAF fault

10.968 V < Battery voltage < 16.046 V

No misfire