Malfunction Criteria And Threshold Value(S)
WARNING: This page is about a different car, the 2006 Suzuki Verona. However, it is still accessible from the selected car via links, so may be relevant.
Sensor signal excursion:
(Oxygen sensor rich voltage - Oxygen sensor lean voltage) < 0.22 V Plausibility fault:
Upstream Oxygen sensor voltage > 0.200 V