Secondary Parameters And Enable Conditions
Electrical check:
Enable Conditions:
IGN = "ON", Eng = "ON"
Batt volts > 10.968 V
Diagnostic = Enabled
SCB Diagnosis:
PWM signal > 1.5154 V (based on VB = 14 V) (1.1718%)
Or
Exhaust Temp. > 39.975 °C
SCG Diagnosis:
PWM signal > 13.94 V (based on VB = 14 V) (99.2187%)
OL Diagnosis:
PWM signal > 1.5154 V (based on VB = 14 V) (1.1718%)
Or
PWM signal < 13.88 V (based on VB = 14 V) (99.218%)
Heater resistance check:
10.9687 V < Battery voltage < 16.0468 V
0.87 V (based on VB = 14 V) (0.39%)
≤ Heater driver PWM duty cycle
≤ 13.9419 V (based on VB = 14 V) (99.60%)
Timer > 120 s
Exhaust gas temperatures at the lambda sensor downstream catalyst
≤ 599.975 °C
Cooling energy of exhaust gas at sensor location >
27685 J
This diagnostic is inhibited if any of the following DTC's are present.
MAF error
MAF/TPS error
DTC P0036: HO2S Heater Control Circuit Bank 1 Sensor 2
DTC P0056: HO2S Heater Control Circuit Bank 2 Sensor 2