Home >> Suzuki >> 2007 >> SX4 Base, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 235 (Engine Control System - Introduction) >> General Description >> OBD System Description - Fuel System Monitor >> Fuel System Lean Bank 1 >> Malfunction Criteria And Threshold Value(S)

Malfunction Criteria And Threshold Value(S)

WARNING: This page is about a different car, the 2006 Suzuki Verona. However, it is still accessible from the selected car via links, so may be relevant.

Adaptation learning area and Lower multiplicative adaptation learning area:

Total duration of "upper limitation of additive adapted factor

Or

Upper limitation of multiplicative adapted factor" > 30 s

Error detection in case of lambda control - dead stop upper limit:

Diagnosis conditions in the area where the lambda control output concerned = fulfilled

And

Bottom threshold of controller output exceeded = true

And

Counter value as a measure of the oil dilution under cold start conditions < 30

=> increment (Total duration of bottom threshold of controller output exceeded)

And

Total duration of bottom threshold of controller output exceeded > 45 s