Home >> Suzuki >> 2007 >> SX4 Base, Automatic >> Repair and Diagnosis >> Transmission >> Automatic Trans >> Automatic Transmission >> General Description >> OBD System Description - Comprehensive Component Rationality Monitor >> Transmission Fluid Temperature Sensor Rationality Monitor >> Enable Conditions

Enable Conditions

ENABLE CONDITIONS

Parameter Minimum Maximum
Battery voltage 9 V
Engine speed 400 rpm
Vehicle speed (more than once) 40 km/h (25 mph)
Shift position "D", "3", "2" or "L" range
"3" position switch Normal condition or not monitored
Engine speed signal (U0100) Normal condition or not monitored
CAN communication (U0073) Normal condition or not monitored