LEMON Manuals: Even more car manuals for everyone
Home >> Suzuki >> 2007 >> SX4 Base, Automatic >> Repair and Diagnosis >> Transmission >> Automatic Trans >> Automatic Transmission >> General Description >> OBD System Description - Comprehensive Component Rationality Monitor >> Input Shaft Speed Sensor Rationality Monitor >> Enable Conditions

Enable Conditions

ENABLE CONDITIONS

Parameter Minimum Maximum
Battery voltage 9 V -
Engine speed 400 rpm -
Output shaft speed 600 rpm -
Shift position "D", "3", "2" or "L" range
Transmission range sensor Normal condition or not monitored
Output shaft speed sensor Normal condition or not monitored
Engine speed signal (U0100) Normal condition or not monitored
CAN communication (U0073) Normal condition or not monitored