LEMON Manuals: Even more car manuals for everyone
Home >> Suzuki >> 2007 >> SX4 Base, Automatic >> Repair and Diagnosis >> External Pages >> Different car >> Section 235 (Engine Control System - Introduction) >> General Description >> OBD System Description - Oxygen Sensor Monitor >> Heated Oxygen Sensor Circuit B1S2 >> Secondary Parameters And Enable Conditions

Secondary Parameters And Enable Conditions

WARNING: This page is about a different car, the 2006 Suzuki Verona. However, it is still accessible from the selected car via links, so may be relevant.

Active check:

This diagnostic is inhibited if any of the following DTC's are present:

CRK fault

CAM fault

MAF fault

O2 sensor fault

CPS fault

ECT fault

TPS fault

FSD fault

TPS/MAF fault

MAP fault

Misfire detected

Enable Conditions:

OL:

IGK "ON"

And HO2S Heater = ON

Exhaust gas temperatures at the lambda sensor downstream catalyst > 349.975 °C

Duration in which lambda probe voltage lies within voltage band to detect fault ≥ 3 s

Or

Delay time for final diagnosis activation ≥ 5 s

This diagnostic is inhibited if any of the following DTC's are present:

O2 downstream sensor faults