Secondary Parameters And Enable Conditions
WARNING: This page is about a different car, the 2006 Suzuki Verona. However, it is still accessible from the selected car via links, so may be relevant.
Active check:
This diagnostic is inhibited if any of the following DTC's are present:
CRK fault
CAM fault
MAF fault
O2 sensor fault
CPS fault
ECT fault
TPS fault
FSD fault
TPS/MAF fault
MAP fault
Misfire detected
Enable Conditions:
- IGN = ON
- ECT > 75 °C
- Lambda sensor heater in controlled Open Loop (normal) operation which is active after dew point detection and an additional time interval of 25 sec.
- Closed Loop operation for lambda-controller and fuel trim correction controller
OL:
IGK "ON"
And HO2S Heater = ON
Exhaust gas temperatures at the lambda sensor downstream catalyst > 349.975 °C
Duration in which lambda probe voltage lies within voltage band to detect fault ≥ 3 s
Or
Delay time for final diagnosis activation ≥ 5 s
This diagnostic is inhibited if any of the following DTC's are present:
O2 downstream sensor faults