Home >> Suzuki >> 2007 >> SX4 Base, Automatic >> Repair and Diagnosis >> External Pages >> Different car >> Section 235 (Engine Control System - Introduction) >> General Description >> OBD System Description - Oxygen Sensor Monitor >> Heated Oxygen Sensor Circuit B1S2 >> Malfunction Criteria And Threshold Value(S)

Malfunction Criteria And Threshold Value(S)

WARNING: This page is about a different car, the 2006 Suzuki Verona. However, it is still accessible from the selected car via links, so may be relevant.

Active check:

Mass airflow integral outside DFCO > 1,000 g

And

Mass airflow integral at rich A/F-mixture (lambda = 0.8) > 80 g

And

Monitoring sensor has not detected "rich"

==> rich voltage threshold: 0.55 V

OL:

Internal resistance of downstream oxygen sensor (Released)

> 60,000 Ω

0.376 V < downstream Oxygen sensor voltage < 0.474 V for 3 sec.