Home >> Suzuki >> 2007 >> SX4 Base, Automatic >> Repair and Diagnosis >> External Pages >> Different car >> Section 235 (Engine Control System - Introduction) >> General Description >> OBD System Description - Oxygen Sensor Monitor >> HO2S Slow Response / Frequency Bank 1 & 2 Sensor 1 >> Secondary Parameters And Enable Conditions

Secondary Parameters And Enable Conditions

WARNING: This page is about a different car, the 2006 Suzuki Verona. However, it is still accessible from the selected car via links, so may be relevant.

Enable Conditions:

IGK "ON"

512 rpm < RPM < 4,608 rpm

15 kg/h < MAF < 400 kg/h

ECT > 50.25 °C

Exhaust gas temperatures at the lambda sensor upstream > 399.97 °C

This diagnostic is inhibited if any of the following DTC's are present:

TPS fault

ECT fault

CRK fault

IV fault

MAF fault

IGC fault

CAM fault

CPS fault

O2 upstream sensor fault

Misfire detected