Secondary Parameters And Enable Conditions
WARNING: This page is about a different car, the 2006 Suzuki Verona. However, it is still accessible from the selected car via links, so may be relevant.
Enable Conditions:
Ignition ON
Engine operating state (Start) = false
10.968 V < Battery voltage < 16.046 V
OL:
PWM signal for CPS opening > 4.2968% < 98.828125%
SCG:
PWM signal for CPS opening < 98.828125%
SCB:
PWM signal for CPS opening > 0.7812%