Connector: C01
ECM COUPLER TERMINALS REFERENCE - CONNECTOR C01
| Terminal | Wire color | Circuit | Terminal | Wire color | Circuit |
|---|---|---|---|---|---|
| 1 | BLU/YEL | Fuel injector No.1 | 31 | BLK | Ground for A/F sensor heater |
| 2 | BLU/WHT | Fuel injector No.2 | 32 | RED | Heater output of A/F sensor |
| 3 | - | - | 33 | BLK | Shield ground for TP sensor circuit |
| 4 | - | - | 34 | - | - |
| 5 | - | - | 35 | - | - |
| 6 | - | - | 36 | BLU | CKP sensor (-) |
| 7 | GRN | P/S pump pressure switch signal | 37 | BLK | A/F sensor signal (-) |
| 8 | - | - | 38 | WHT | A/F sensor signal (+) |
| 9 | - | - | 39 | BLK/RED | Ground for HO2S |
| 10 | - | - | 40 | WHT | TP sensor (sub) signal |
| 11 | BRN | Oxygen signal of HO2S | 41 | BLK | Ground for TP sensor |
| 12 | RED/BLU | A/C refrigerant pressure sensor signal | 42 | YEL | IMT valve actuator (+) |
| 13 | BLU/BLK | EVAP canister purge valve output | 43 | YEL/BLK | IMT valve actuator (-) |
| 14 | GRY/RED | Output of 5 V power source for A/C refrigerant pressure sensor | 44 | YEL | Output of throttle actuator |
| 15 | BLK | Ground for ECM | 45 | BLU | Output of throttle actuator |
| 16 | BLU/RED | Fuel injector No.3 | 46 | - | - |
| 17 | BLU/ORN | Fuel injector No.4 | 47 | RED/BLU | Heater output of HO2S |
| 18 | GRN | Ignition coil No.4 | 48 | BLK/ORN | Ground for ECM |
| 19 | GRN/BLK | Ignition coil No.3 | 49 | WHT | CAN (low) communication line (active low signal) to TCM |
| 20 | GRN/WHT | Ignition coil No.2 | 50 | RED | CAN (high) communication line (active high signal) to TCM |
| 21 | GRN/YEL | Ignition coil No.1 | 51 | PNK | CKP sensor (+) |
| 22 | YEL/GRN | Starting motor signal | 52 | RED/YEL | CMP sensor signal |
| 23 | - | - | 53 | RED | Output for 5 V power source of TP sensor |
| 24 | LT | GRN ECT sensor signal | 54 | GRN | TP sensor (main) signal |
| 25 | LT GRN/BLK | IAT sensor signal | 55 | - | - |
| 26 | PNK/BLK | MAF sensor signal | 56 | RED | Knock sensor signal |
| 27 | GRY | Ground for MAF sensor | 57 | GRY/BLU | Ground for sensors |
| 28 | BLU/YEL | Generator control signal output | 58 | BLK/ORN | Ground for ECM |
| 29 | BLK | Ground for ECM | 59 | - | - |
| 30 | BLK | Ground for ECM | 60 | - | - |