Electric Load Signal Circuit Check: Troubleshooting
NOTE:
- Before performed troubleshooting, be sure to read the PRECAUTIONS OF ECM CIRCUIT INSPECTION .
- When measuring circuit voltage, resistance and/or pulse signal at ECM connector, connect the special tool to ECM and/or the ECM connectors referring to INSPECTION OF ECM AND ITS CIRCUITS .
TROUBLESHOOTING CHART
| Step | Action | YES | NO |
|---|---|---|---|
| 1 | DTC check
Is there DTC U0073 and/or U0121? |
Go to applicable DTC diag. flow. | Go to Step 2. |
| 2 | Electric load signal circuit check
Is check result satisfactory? |
Electric load signal circuit is in good condition | Check defective signal circuit. |