A/C Condenser Cooling Fan Control System Inspection: Troubleshooting
TROUBLESHOOTING CHART
| Step | Action | YES | NO |
|---|---|---|---|
| 1 | Check A/C condenser fan control system Is A/C condenser fan started when A/C is operating? |
System is in good condition. | Go to Step 2. |
| 2 | Check A/C condenser fan relay and its circuit
Is DTC P0482 displayed? |
Go to DTC P0481: FAN 2 CONTROL CIRCUIT (NON-EVAP-LEAK-CHECK MODEL) . | Go to Step 3. |
| 3 | Check A/C refrigerant
Is it good condition? |
Go to Step 4. | Recharge refrigerant. |
| 4 | Check wire circuit
Is voltage 10 - 14V? |
Go to Step 7. | Go to Step 5. |
| 5 | Check wire circuit
Is voltage 10 - 14 V? |
Faulty A/C compressor relay. | Go to Step 6. |
| 6 | Check wire circuit
Is resistance infinity? |
Open wire in "BLU/YEL" circuit. If OK, go to Step 7. | "BLU/YEL" wire shorted to ground circuit. |
| 7 | Check wire circuit
Is resistance infinity? |
Go to Step 8. | "RED" wire shorted to ground circuit. |
| 8 | Check A/C condenser cooling fan control relay
Is result in good condition? |
Go to Step 9. | Replace relay. |
| 9 | Check wire circuit
Is voltage 10 - 14 V? |
Go to Step 10. | Open wire in "RED" circuit. |
| 10 | Check wire circuit
Is resistance below 1 Ω? |
Go to Step 11. | Open or high resistance wire in "BLK" circuit. |
| 11 | Check A/C condenser cooling fan
Is it good condition? |
Substitute a known-good ECM and recheck. | Faulty A/C condenser cooling fan. |