Malfunction Criteria And Threshold Value(S)

Additive adaptation learning area and multiplicative adaptation learning area:

Counter value as a measure of the oil dilution under cold start conditions < 30

And

Total duration of "upper limitation of additive adapted factor

or

upper limitation of multiplicative adapted factor of lower area" > 30 s

Error detection in case of lambda control - dead stop lower Limit:

Diagnosis conditions in the area where the lambda control output concerned = fulfilled

And

bottom threshold of controller output exceeded = true