Home >> Suzuki >> 2006 >> Verona Base >> Repair and Diagnosis >> Engine Performance >> System >> Engine Control System - Introduction >> General Description >> OBD System Description - EGR System Monitor >> Exhaust Gas Recirculation Control Circuit Diagnosis >> Secondary Parameters And Enable Conditions

Secondary Parameters And Enable Conditions

Ignition ON

Battery Voltage matches OBD conditions

10.968 V < Battery voltage < 16.046 V

SCP: Final EGR valve duty cycle < 0.751%

SCG: Final EGR valve duty cycle < 96.249%

OC: Final EGR valve duty cycle > 14.999%

Or

Final EGR valve duty cycle < 96.249%