Secondary Parameters And Enable Conditions
Enable Conditions:
- Flag for crankshaft acquisition synchronized = ON
- No Crankshaft error
- 0 < Engine Speed calculated on last crankshaft tooth period < 416 rpm
- Engine Speed > 512 rpm
Signal Implausible/Signal Missing:
Enable Conditions:
Crankshaft acquisition active
No Crankshaft error
0 < Engine Speed calculated on last crankshaft tooth period < 416 rpm
Loss of Synchronization:
Flag for crankshaft acquisition synchronized = ON
No Crankshaft error
0 < Engine Speed calculated on last crankshaft tooth period < 416 rpm
Implausible Tooth Period:
Engine running = true
Crankshaft limp-home mode = false
No Crankshaft error
0 < Engine Speed calculated on last crankshaft tooth period < 416 rpm