Enable Conditions
Normal Idle conditions = TRUE
AND Canister Purge Fuel Flow ≤ 100
AND Barometric Pressure > 72 kPa
AND Engine running long enough ≥ 2 s
AND Air Intake Temperature ≥ -20 °C
AND Coolant Temperature ≥ -10 °C
AND Ignition Voltage ≥ 11 V
AND Ignition Voltage ≤ 16 V
AND Enable timer > 3 s
AND Instrumentation slew commanded = FALSE
AND OFVC Device Control Active