LEMON Manuals: Even more car manuals for everyone
Home >> Suzuki >> 2005 >> Verona EX >> Repair and Diagnosis >> Transmission >> Automatic Transmission >> Diagnostic Information and Procedures >> Transaxle Fluid Level Service Procedure >> Methods for Locating Leaks >> Powder Method

Powder Method

  1. Thoroughly clean the suspected leak area.
  2. Apply an aerosol type powder (foot powder) to the suspected leak area.
  3. Drive the vehicle for approximately 25 km (15 miles) or until the transaxle reaches normal operating temperature (88 °C, 190 °F).
  4. Turn the engine OFF.
  5. Inspect the suspected leak area and trace the leak path through the powder to find the source of the leak.
  6. Make the necessary repairs.