LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2025 >> Forester Wilderness >> Repair and Diagnosis >> External Pages >> Different car >> Section 21 (Wiper System & Washer System) >> Wiper Relay Unit >> Inspection

Wiper Relay Unit: Inspection

WARNING: This page is about a different car, the 2023 Subaru Ascent. However, it is still accessible from the selected car via links, so may be relevant.
  1. Check the resistance between relay terminals.
    G13200933Courtesy of SUBARU OF AMERICA, INC.
    Inspection conditions Terminal No. Standard
    Always A1 - A2 Less than 1 Ω
    A4 - A1 1 MΩ or more
    A3 - A4 1 MΩ or more
    Apply battery voltage between terminals B3 (+) and B2 (-). (Lo output condition) A1 - A2 1 MΩ or more
    A4 - A1 Less than 1 Ω
    A3 - A4 1 MΩ or more
    Apply battery voltage between terminals B1 (+) and B2 (-). (Hi output condition) A1 - A2 1 MΩ or more
    A4 - A1 1 MΩ or more
    A3 - A4 Less than 1 Ω
  2. When measurement value is different from the specification, replace the wiper relay unit.