Starter Relay: Inspection
- Check that the starter relay and starter cut relay do not have deformation, cracks and any other damage.
- Measure the Ω between the starter relay and starter cut relay terminals.
- Starter relay
Terminal No. Inspection conditions Standard 3 - 4 Always 1 MΩ or more 3 - 4 Apply battery voltage between terminals 1 and 2. Less than 1 Ω - Starter cut relay
Terminal No. Inspection conditions Standard 3 - 4 Always 1 MΩ or more 3 - 4 Apply battery voltage between terminals 1 and 2. Less than 1 Ω - Starter relay