| 0020H |
Timeout due to unstable load |
Occupant detection control module judged the current situation as error because the over-specified load change occurred during rezeroing. |
Perform the system rezero adjustment again from the beginning at a stable place where vehicle vibration hardly occurs. |
| 0021H |
FL sensor upper limit error |
Rezeroing cannot be executed because the load value of FL sensor exceeds the upper limit of rezero adjustment range. |
Check that the seat is in proper position and fixed securely, and perform the system rezero adjustment again from the beginning. If the same code appears again, replace the seat assembly. Ref. to SEATS>FRONT SEAT
. |
| 0022H |
FL sensor lower limit error |
Rezeroing cannot be executed because the load value of FL sensor exceeds the lower limit of rezero adjustment range. |
Check that the seat is in proper position and fixed securely, and perform the system rezero adjustment again from the beginning. If the same code appears again, replace the seat assembly. Ref. to SEATS>FRONT SEAT
. |
| 0023H |
FR sensor upper limit error |
Rezeroing cannot be executed because the load value of FR sensor exceeds the upper limit of rezero adjustment range. |
Check that the seat is in proper position and fixed securely, and perform the system rezero adjustment again from the beginning. If the same code appears again, replace the seat assembly. Ref. to SEATS>FRONT SEAT
. |
| 0024H |
FR sensor lower limit error |
Rezeroing cannot be executed because the load value of FR sensor exceeds the lower limit of rezero adjustment range. |
Check that the seat is in proper position and fixed securely, and perform the system rezero adjustment again from the beginning. If the same code appears again, replace the seat assembly. Ref. to SEATS>FRONT SEAT
. |
| 0025H |
RL sensor upper limit error |
Rezeroing cannot be executed because the load value of RL sensor exceeds the upper limit of rezero adjustment range. |
Check that the seat is in proper position and fixed securely, and perform the system rezero adjustment again from the beginning. If the same code appears again, replace the seat assembly. Ref. to SEATS>FRONT SEAT
. |
| 0026H |
RL sensor lower limit error |
Rezeroing cannot be executed because the load value of RL sensor exceeds the lower limit of rezero adjustment range. |
Check that the seat is in proper position and fixed securely, and perform the system rezero adjustment again from the beginning. If the same code appears again, replace the seat assembly. Ref. to SEATS>FRONT SEAT
. |
| 0027H |
RR sensor upper limit error |
Rezeroing cannot be executed because the load value of RR sensor exceeds the upper limit of rezero adjustment range. |
Check that the seat is in proper position and fixed securely, and perform the system rezero adjustment again from the beginning. If the same code appears again, replace the seat assembly. Ref to SEATS>Front Seat
. |
| 0028H |
RR sensor lower limit error |
Rezeroing cannot be executed because the load value of RR sensor exceeds the lower limit of rezero adjustment range. |
Check that the seat is in proper position and fixed securely, and perform the system rezero adjustment again from the beginning. If the same code appears again, replace the seat assembly. Ref. to SEATS>FRONT SEAT
. |
| 0029H |
Sensor malfunction |
Rezeroing cannot be performed due to sensor malfunction during rezeroing. |
Read [Occupant Detection] DTCs, and perform the diagnosis for the displayed DTCs. Ref. to OCCUPANT DETECTION(DIAGNOSTICS)>DIAGNOSTIC TROUBLE CODE (DTC)
. |
| 0030H |
Memory access error |
Rezeroing cannot be performed due to data flash malfunction during rezeroing. |
Read [Occupant Detection] DTCs, and perform the diagnosis for the displayed DTCs. Ref. to OCCUPANT DETECTION(DIAGNOSTICS)>DIAGNOSTIC TROUBLE CODE (DTC)
. |