LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2024 >> Forester Base >> Repair and Diagnosis >> Electrical >> Charging Systems >> Engine Starting System & Charging System >> Battery >> Charge >> Normal Charge (Constant Current Charge) >> Judgment Of Charge Completion

Judgment Of Charge Completion

  1. Specific gravity of electrolyte should be held within the specific range of 1.250 - 1.290 for one hour or more.
  2. Voltage while charging should be held within the specified range of 15.0 - 16.8 V for one hour or more.
  3. Gas is actively generated in all cells.
  4. The amount of charge reaches 1.2 - 1.5 times of the amount of discharge.
    NOTE: The amount of discharge/charge can be calculated by the following formula.
    Amount of discharge (Ah) = remaining capacity calculated by specific gravity (%) x 5 hour rate capacity (Ah)
    Amount of charge (Ah) = Charging current value (A) x Time for charging