Combination Meter: Installation
CAUTION:
- Make sure the electrical connector is connected securely.
- Make sure that each meter operates normally.
- For the model without keyless access with push button start except for C0 model, when the combination meter assembly is replaced, perform the registration of immobilizer system. For detailed operation procedure, refer to "Type G" described in "REGISTRATION MANUAL FOR IMMOBILIZER".
- When the combination meter assembly is replaced, perform the variant work. Ref. to INSTRUMENTATION/DRIVER INFO>COMBINATION METER SYSTEM>OPERATION>VARIANT WORK .
- Install the combination meter assembly.
- Connect the connector, and install the visor assembly.
- Install the cover visor.
- Install the grille ventilation assembly center.
- Install the ornament assembly driver.
- Connect the ground terminal to battery sensor. Ref. to REPAIR CONTENTS>NOTE>BATTERY .
- When the combination meter assembly has been replaced, read the [Combination Meter] customizing information. Ref. to COMMON DIAGNOSTIC OPERATIONS>CUSTOMIZE>OPERATION>SAVE SETTINGS / READ SETTINGS .