DTC B2784: Antenna Circuit (Push Engine Switch)
DTC detecting condition:
When the keyless access control module receives the data of Abnormal antenna coil from transponder key amplifier via transponder communication (communication between keyless access control module- push button ignition SW) during initial operation of transponder collation.
Trouble symptom:
The keyless access function may not be operable.
Wiring diagram:
Keyless access with push button start system Ref. to WIRING SYSTEM>KEYLESS ACCESS WITH PUSH BUTTON START SYSTEM>WIRING DIAGRAM .
- For replacement procedure of keyless access control module, refer to the "REGISTRATION MANUAL FOR IMMOBILIZER" provided as a separate volume.
- Before performing diagnosis, refer to "CAUTION" in "General Description". Ref. to KEYLESS ACCESS WITH PUSH BUTTON START (DIAGNOSTICS)>GENERAL DESCRIPTION>CAUTION .
- CHECK STEERING LOCK CONTROL MODULE
.
- Disconnect the push button ignition switch connector.
- Disconnect the keyless access control module connector.
- Using a tester, measure the resistance between the push button ignition switch connector and the keyless access control module connector.
Connector & terminal
(i150) No. 9 - (i241) No. 19:
(i150) No. 10 - (i241) No. 22:
(i150) No. 14 - (i241) No. 21:
(i150) No. 8 - (i241) No. 24:
Is the resistance less than 1 Ω?
Yes: Go to 2.
No: Repair or replace the open circuit of harness.
- CHECK HARNESS (GROUND SHORT CIRCUIT)
.
Using a tester, measure the resistance between the push button ignition switch connector and chassis ground.
Connector & terminal
(i150) No. 14 - Chassis ground:
(i150) No. 9 - Chassis ground:
(i150) No. 10 - Chassis ground:
Is the resistance 10 kΩ or more?
Yes: Go to 3.
No: Repair or replace the short circuit of the harness.
- CHECK PUSH BUTTON IGNITION SWITCH
.
- Replace the push button ignition switch. Ref. to SECURITY AND LOCKS>PUSH BUTTON IGNITION SWITCH .
- Connect the disconnected connectors.
- Turn the ignition switch to ON.
- Using the Subaru Select Monitor, perform the clear memory of [Keyless Access with Push Button Start (Collation)]. Ref. to COMMON (DIAGNOSTICS)>CLEAR MEMORY .
- Read the DTC of [Keyless Access with Push Button Start (Collation)] using the Subaru Select Monitor. Ref. to KEYLESS ACCESS WITH PUSH BUTTON START (DIAGNOSTICS)>DIAGNOSTIC TROUBLE CODE (DTC) .
Is DTC B2784 displayed? (Current code)
Yes: Replace the keyless access control module. Ref. to SECURITY AND LOCKS>KEYLESS ACCESS CONTROL MODULE .
No: Malfunction occurred in the push button ignition switch.