Execution Condition
SECONDARY PARAMETERS AND EXECUTION CONDITION - DIAGNOSIS 1 (POWER SUPPLY SHORT)
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | 9.44 V or more |
| FET and SW statuses | Status A |
SECONDARY PARAMETERS AND EXECUTION CONDITION - DIAGNOSIS 2 (GROUND SHORT)
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | 9.44 V or more |
| FET and SW statuses | Status B |
SECONDARY PARAMETERS AND EXECUTION CONDITION - DIAGNOSIS 3 (OPEN CIRCUIT)
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | 9.44 V or more |
| FET and SW statuses | Status A (condition 1) Status B (condition 2) |
SECONDARY PARAMETERS AND EXECUTION CONDITION - DIAGNOSIS 4 (SHORT CIRCUIT, OVERCURRENT)
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | 9.44 V or more |
| FET and SW statuses | Status C |
FET AND SW STATUSES
| Condition | FET1 | FET2 | SW1 | SW2 |
|---|---|---|---|---|
| Status A | OFF | OFF | OFF | ON |
| Status B | OFF | OFF | ON | OFF |
| Status C | ON | ON | OFF | OFF |