Execution Condition
SECONDARY PARAMETERS AND EXECUTION CONDITION - DIAGNOSIS 1: THROTTLE POSITION IS OUT OF RANGE
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | 6 V or more |
| Micro-computer (CPU failure) (P0606) | Under detection |
SECONDARY PARAMETERS AND EXECUTION CONDITION - DIAGNOSIS 2: INTAKE AIR AMOUNT IS OUT OF RANGE
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | 6 V or more |
| Micro-computer (CPU failure) (P0606) | Under detection |
SECONDARY PARAMETERS AND EXECUTION CONDITION - DIAGNOSIS 3: ALL TIME MONITORING
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | 6 V or more |
SECONDARY PARAMETERS AND EXECUTION CONDITION - DIAGNOSIS 4: ACTUAL OPENING ANGLE CHANGE AMOUNT IS SMALL
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | 6 V or more |
| Actual opening angle change amount | More than 0.89 %/msec |
SECONDARY PARAMETERS AND EXECUTION CONDITION - DIAGNOSIS 5: ACTUAL OPENING ANGLE CHANGE AMOUNT IS LARGE
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | 6 V or more |
| Actual opening angle change amount | More than 2.22 %/msec |
SECONDARY PARAMETERS AND EXECUTION CONDITION - DIAGNOSIS 6: ACTUAL OPENING ANGLE DOES NOT CHANGE
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | More than 6 V |
| Continuous time when actual opening angle changing amount is 0%/msec | 5000 ms or more |