Execution Condition
- ENGINE TYPE FB
Secondary parameters Execution condition 12 V battery system voltage 9 V or more Transmission range Drive
or
Reverse(Measured turbine shaft speed/Measured secondary pulley shaft speed) 0.359 or more
and
2.895 or less - ENGINE TYPE FA
Secondary parameters Execution condition 12 V battery system voltage 10 V or more Engine speed 400 rpm or more