Execution Condition
SECONDARY PARAMETER AND EXECUTION CONDITION - DIAGNOSTIC METHOD 1
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | 10.9 V or more |
| Barometric pressure | 75.1 kPa (563 mmHg, 22.2 inHg) or more |
| Time of main feedback operation | 3000 ms or more |
| Engine speed | 1000rpm or more |
| Amount of intake air | 10g/s (0.35 oz/s) or more |
SECONDARY PARAMETER AND EXECUTION CONDITION - DIAGNOSTIC METHOD 2
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | 10.9 V or more |
| Barometric pressure | 75.1 kPa (563 mmHg, 22.2 inHg) or more |
| Main feedback | 3000 ms or more |
| Engine speed | 1000rpm or more |
| Amount of intake air | 10g/s (0.35 oz/s) or more |