Converter Case: Disassembly
- Remove the drain plug (A) using TORX® bit T70.
- Remove the overflow plug (B).
- Remove the line pressure sensor. Ref. to CONTINUOUSLY VARIABLE TRANSMISSION (TR580 (WILDERNESS))>LINE PRESSURE SENSOR>REMOVAL .
- Remove the primary pressure sensor. Ref. to CONTINUOUSLY VARIABLE TRANSMISSION (TR580 (WILDERNESS))>PRIMARY PRESSURE SENSOR>REMOVAL .
- Remove the plugs and oil guide.
(A) Oil guide - Remove the stud bolt.