Cooling system Electric fan + Forced engine coolant circulation system
Total engine coolant capacity L (US qt, Imp qt) Engine side Approx. 8.0 (8.5, 7.0)
Inverter assembly side Approx. 3.4 (3.6, 3.0)
Water pump Type Centrifugal impeller type
Pump characteristics Discharge rate L (US gal, Imp gal)/min 214 (56.5, 47.1) or more
Engine coolant temperature °C (°F) 80 (176)
Engine coolant concentration % 50
System pressure kPa (mAq) 88 (9.0)
Pump speed r/min 8, 580
Impeller diameter mm (in) 56 (2.20)
Number of impeller vanes pcs. 7
Pump pulley effective diameter mm (in) 100 (3.94)
Inverter water pump Motor input W 70 or less
Flow rate L (US gal, Imp gal)/min MAX 13 (3.4, 2.9) or more
Thermostat Type Wax pellet type
Starting temperature to open °C (°F) 90 - 94 (194 - 201)
Full open temperature °C (°F) 100 (212)
Valve lift mm (in) 8.0 (0.315) or more
Valve opening size mm (in) 32 (1.26)
Radiator fan Motor input W Main fan 160
Sub fan 160
Fan outer diameter mm (in) Main fan 300 (11.8)
Sub fan 300 (11.8)
Number of fan blades pcs. Main fan 9
Sub fan 11
Radiator Type Side flow, pressure type
Core dimensions mm (in) Width x Height x Thickness (649.2 x 376.2 x 27) (25.56 x 14.81 x 1.06)
Pressure range in which cap valve is open kPa (kg/cm2, psi) Positive pressure side Standard 93 - 123 (0, 95 - 1, 25, 14 - 18)
Limit 83 (0, 85, 12)
Negative pressure side Standard The barometric pressure or less
Fin shape Corrugated fin
Water tank pipe Pressure range in which cap valve is open kPa (kg/cm2 , psi) Positive pressure side Standard 122 - 152 (1, 24 - 1, 55, 18 - 22)
Limit 112 (1, 14, 16)
Reservoir tank Capacity L (US qt, Imp qt) 0.45 (0.476, 0.396)
Inverter tank Capacity L (US qt, Imp qt) 0.61 (0.645, 0.537)
Pressure range in which cap valve is open kPa (kg/cm2, psi) Positive pressure side Standard 93 - 123 (0.95 - 1.25, 14 - 18)
Limit 83 (0, 85, 12)
Negative pressure side Standard -1.0 - -4.9 or less (-0.01 - -0.05, -0.1 - -0.7)

Engine coolant: 