Diagnostic Method
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| |Barometric pressure - Intake manifold pressure at start| | 12.12 kPa (90.9 mmHg, 3.58 inHg) or more |
Time needed for diagnosis: Less than 1 s
Malfunction indicator light illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.