Diagnostic Method
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| <For electronic throttle control power supply>Electronic throttle control power voltage | Less than 6 V |
| <For electronic throttle control relay monitor> Electronic throttle control relay monitor voltage | 1 V or less |
Time needed for diagnosis: 510 ms
Malfunction indicator light illumination: Illuminates as soon as a malfunction occurs.