<Final ignition timing diagnosis: Idle>
Judge as NG when the following conditions are established.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value | DTC | ||
|---|---|---|---|---|
| <N range> Final ignition timing - Ignition timing during CSERS(1) |
More than 8.5°CA | P050B | ||
| <D range> Final ignition timing - Ignition timing during CSERS(1) |
More than 8.5°CA | |||
|
||||