52 Ω Or Less (Power Unit Can)
Wiring diagram:
CAN communication system Ref. to WIRING SYSTEM>CAN COMMUNICATION SYSTEM>WIRING DIAGRAM .
- CHECK BETWEEN RELATED LINES AND MAIN WIRING HARNESS
.
- Turn the ignition switch to OFF.
- Disconnect the central gateway control module connector.
- Using a tester, measure the resistance between the central gateway control module connectors.
Connector & terminal
(i366) No. 23 - (i366) No. 24:
Is the resistance less than 10 Ω?
Yes: Go to 2.
No: Go to 3.
- CHECK MAIN WIRING HARNESS AND RELATED LINES
.
With a tester connected, disconnect control module connectors in order.
Connector & terminal
(i366) No. 23 - (i366) No. 24:
Is there any control module whose condition has changed from short state?
Yes: Replace the control module whose resistance has changed.
No: Repair or replace the short circuit of the harness between the central gateway control module and ECM.
- CHECK CONTROL MODULE
.
- Disconnect the connectors of the ECM and central gateway control module.
- Using a tester, measure the resistance between control module terminals.
Connector & terminal
(B134) No. 6 - (B134) No. 5:
(i366) No. 23 - (i366) No. 24:
Is the resistance 114 - 126 Ω?
Yes: Go to 4.
No: Replace the control module whose end resistance value is out of the specified range.
- CHECK HARNESS
.
Using a tester, measure the resistance between the central gateway control module connector terminals.
Connector & terminal
(i366) No. 23 - (i366) No. 24:
Is the resistance 1 MΩ or more?
Yes: Go to 6.
No: Go to 5.
- CHECK CONTROL MODULE
.
With a tester connected, disconnect control modules in order.
Connector & terminal
(i366) No. 23 - (i366) No. 24:
Are there any control modules whose resistance changed to 1 MΩ or more?
Yes: Replace the control module that has changed.
No: Repair or replace the harness part which has resistance component.
- CHECK CENTRAL GATEWAY CONTROL MODULE
.
- Connect the central gateway control module connector.
- Disconnect the VDC control module connector.
- Using a tester, measure the resistance between terminals in VDC control module connector.
Connector & terminal
(B310) No. 5 - (B310) No. 19:
Is the resistance 1 MΩ or more?
Yes: CAN communication circuit is normal.
No: Replace the central gateway control module. Ref. to SECURITY AND LOCKS>CENTRAL GATEWAY CONTROL MODULE .