Remote Control Mirror Switch: Inspection
- Check the resistance between switch door mirror terminals.
- Changeover switch RH
Terminal No. Inspection conditions Standard 2 - 6
2 - 10OFF 1 MΩ or more 2 - 10
11 - 6UP Less than 1 Ω 2 - 11
10 - 6DOWN Less than 1 Ω 2 - 12
10 - 6LEFT Less than 1 Ω 2 - 10
12 - 6RIGHT Less than 1 Ω - Changeover switch LH
Terminal No. Inspection conditions Standard 2 - 6
2 - 7OFF 1 MΩ or more 2 - 7
8 - 6UP Less than 1 Ω 2 - 8
7 - 6DOWN Less than 1 Ω 2 - 9
7 - 6LEFT Less than 1 Ω 2 - 7
9 - 6RIGHT Less than 1 Ω - Changeover switch RH
- Apply battery voltage between the switch door mirror terminals to check lighting condition of illumination inside the switch.CAUTION: When applying battery voltage, do not mix up the positive (+) side and the negative (-) side.
Incorrect polarity connection may cause LED damage inside the switch.Terminal No. Inspection conditions Specification 3 (+) - 5 (-) Apply battery voltage. Light ON - Replace the switch power window main if it is found defective from the inspection result.