Adjustment Value Clear

WARNING: This page is about a different car, the 2022 Subaru WRX. However, it is still accessible from the selected car via links, so may be relevant.

Perform when replacing stereo camera. (Do not perform when performing stereo camera re-adjustment and inspection)

  1. Using the Subaru Select Monitor, select [Clear adjustment value] in [Work Support] of [EyeSight]. Ref. to COMMON (DIAGNOSTICS)>WORK SUPPORT
  2. When [Clear the adjustment value. Caution! Do not perform the procedure with any conditions other than specified in the service information.] is displayed, select [OK].
    NOTE:

    After camera adjustment, the function will be enabled, when the ignition switch is turned to OFF and the system is restarted. 

  3. When [Clearing adjustment value...] is displayed, wait until it finishes.
  4. When the adjustment value clear operation is finished correctly, [Adjustment value clear OK! The adjustment value clear was finished correctly. Turn the IGN SW to OFF for five seconds or more. (CODE 1F00)] is displayed. Select [OK] to finish.
    CAUTION:

    When [Adjustment value clear NG! The adjustment value clear failed. (CODE 1F01)] or [[4203] Communication error has occurred. Turn OFF the ignition switch and re-adjust] is displayed, check the DTC of stereo camera (current code, history code). Ref. to  COMMON (DIAGNOSTICS)>DIAGNOSTIC TROUBLE CODE (DTC) 

  5. Turn the ignition switch to OFF and wait for approx. 5 seconds or more.
    CAUTION:

    If the ignition switch OFF period is short, the adjustment value clear operation cannot be performed correctly. 

  6. Next, perform the camera all adjustment mode (replacement/removal). Ref. to EYESIGHT>CAMERA ADJUSTMENT, INSPECTION>PROCEDURE>CAMERA ALL ADJUSTMENT MODE (REPLACEMENT/REMOVAL)