Home >> Subaru >> 2021 >> WRX Base >> Repair and Diagnosis (Single Page) >> Engine Performance >> Testing & Diagnosis >> Engine Control System (Diagnostics) (2.0L) (4 Of 4) >> Diagnostic Procedure with Diagnostic Trouble Code (DTC) >> DTC P24B9: EVAP System Leak Detection Pump Pressure Sensor Circuit Range/Performance >> Execution Condition

Execution Condition

Secondary parameters Execution condition
Elapsed time after ignition switch is turned to ON ≥ 0.5 s and < 60 s
Soaking time ≥ 60 s
Evaporative Leak Check Module vacuum pump Not in operation
Evaporative Leak Check Module switching valve Open
Purge control Not in operation