Execution Condition
EXECUTION CONDITION - DIAGNOSIS 1
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage Soaking time Block heater judgment Block heater operation |
≥ 10.9 V ≥ 21600 s Completed Not in operation |
EXECUTION CONDITION - DIAGNOSIS 2
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage Engine coolant temperature Integrated value of intake air amount Number of experiences under following driving conditions
|
≥ 10.9 V ≥ 60°C (140°F) ≥ 5500 g (194 oz) ≥ 3 times ≥ 10 s ≥ 40 km/h (24.9 MPH) ≥ 15 g/s (0.5 oz/s) ≥ 15 s < 4 km/h (2.5 MPH) |