Diagnostic Method
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE - DIAGNOSIS 1
| Malfunction Criteria | Threshold Value |
|---|---|
| Defective operation signal from electronic wastegate valve driving IC | ON |
JUDGMENT VALUE - DIAGNOSIS 2
| Malfunction Criteria | Threshold Value |
|---|---|
| Electronic wastegate valve voltage | Less than 0.032 V |
Time needed for diagnosis : 2500 ms
Malfunction indicator light illumination : Illuminates as soon as a malfunction occurs.