Active Test: List
NOTE:
Some items are not displayed according to destination area or vehicle equipment condition.
| Active test item | Range | Contents | Execution condition | ||||||
|---|---|---|---|---|---|---|---|---|---|
| In-vehicle Air Temperature setting | -72.47 - 193.82°C | Set in-vehicle sensor readings. Adjusting the in-vehicle sensor value to use for A/C control is useful for reproduction test in faulty events. | Ignition switch ON
NOTE:
Engine ON is recommended.
|
||||||
| Ambient Air Temperature Setting | -40 - 80°C | Set ambient sensor readings. Adjusting the ambient sensor value to use for A/C control is useful for reproduction test in faulty events. | Ignition switch ON
NOTE:
Engine ON is recommended.
|
||||||
| Quantity of Sunload Setting | 0 - 4448 W/m2 | Set sunload sensor readings. Adjusting the sunload sensor value to use for A/C control is useful for reproduction test in faulty events. | Ignition switch ON
NOTE:
Engine ON is recommended.
|
||||||
| Heater Water Temperature Setting | -40 - 214°C | Set coolant temperature sensor readings. Adjusting the coolant temperature sensor value to use for A/C control is useful for reproduction test in faulty events. | Engine ON | ||||||
| AUTO switch mode setting | ON | Transmit ON signal of AUTO switch contact. By operating A/C with the signal, it is possible to judge whether the control is faulty or the switch (center information display) is faulty. | Ignition switch ON
NOTE:
Engine ON is recommended.
|
||||||
| Air mix door actuator target open (driver's side) | -32.68 - 133.33 % | Set the driver's seat air mix door actuator opening angle. Useful for reproduction test in faulty events. | Ignition switch ON
NOTE:
Engine ON is recommended.
|
||||||
| Air mix door actuator target open (passenger's side) | -32.68 - 133.33 % | Set the passenger's seat air mix door actuator opening angle. Useful for reproduction test in faulty events.(1) | Ignition switch ON
NOTE:
Engine ON is recommended.
|
||||||
| Fresh/Rec Air Dr Act Trgt Open Angle | -32.68 - 133.33 % | Set the intake door actuator opening angle. Useful for reproduction test in faulty events. | Ignition switch ON
NOTE:
Engine ON is recommended.
|
||||||
| Mode Door Actuator Opening Angle Target | -32.68 - 133.33 % | Set the mode door actuator opening angle. Useful for reproduction test in faulty events. | Ignition switch ON
NOTE:
Engine ON is recommended.
|
||||||
| Blower Fan Level Setting | 0 - 255
NOTE:
Input up to 255 is possible, but 100 - 255 is the same.
|
Set the blower fan level. Useful for reproduction test in faulty events. | Ignition switch ON
NOTE:
|
||||||
| A/C Change Setting | ON/OFF | Set the compressor operation request. Useful for reproduction test in faulty events. |
|
||||||
| Rear Defogger Setting | ON/OFF | Transmit the rear defogger switch contact signal. By operating A/C with the signal, it is possible to judge whether the control is faulty or the switch (center information display) is faulty. | Ignition switch ON
NOTE:
Engine ON is recommended.
|
||||||
| Variable Flow Change Solenoid Duty | 0 - 100% | Set Duty value of variable flow change solenoid valve. Useful for reproduction test in faulty events.
NOTE:
The setting value may not be obtained due to A/C circuit protection.
|
|
||||||
| PTC steps | 0 - 3 | Set PTC level. Useful for reproduction test in faulty events.(2)
NOTE:
The setting value may not be obtained due to power supply circuit protection.
|
|
||||||
| Heater core temperature setting | -40 - 214°C | Set the heater core sensor readings. Adjusting the heater core sensor value to use for A/C control is useful for reproduction test in faulty events. | Ignition switch ON
NOTE:
Engine ON is recommended.
|
||||||
| Humidity Setting | 0 - 100% | Set humidity sensor readings. Adjusting the humidity sensor value to use for A/C control is useful for reproduction test in faulty events.(3) | Ignition switch ON
NOTE:
Engine ON is recommended.
|
||||||
|
|||||||||