Active test item Range Contents Execution condition
In-vehicle Air Temperature setting -72.47 - 193.82°C Set in-vehicle sensor readings. Adjusting the in-vehicle sensor value to use for A/C control is useful for reproduction test in faulty events. Ignition switch ON
NOTE: Engine ON is recommended.
Ambient Air Temperature Setting -40 - 80°C Set ambient sensor readings. Adjusting the ambient sensor value to use for A/C control is useful for reproduction test in faulty events. Ignition switch ON
NOTE: Engine ON is recommended.
Quantity of Sunload Setting 0 - 4448 W/m2 Set sunload sensor readings. Adjusting the sunload sensor value to use for A/C control is useful for reproduction test in faulty events. Ignition switch ON
NOTE: Engine ON is recommended.
Heater Water Temperature Setting -40 - 214°C Set coolant temperature sensor readings. Adjusting the coolant temperature sensor value to use for A/C control is useful for reproduction test in faulty events. Engine ON
AUTO switch mode setting ON Transmit ON signal of AUTO switch contact. By operating A/C with the signal, it is possible to judge whether the control is faulty or the switch (center information display) is faulty. Ignition switch ON
NOTE: Engine ON is recommended.
Air mix door actuator target open (driver's side) -32.68 - 133.33 % Set the driver's seat air mix door actuator opening angle. Useful for reproduction test in faulty events. Ignition switch ON
NOTE: Engine ON is recommended.
Air mix door actuator target open (passenger's side) -32.68 - 133.33 % Set the passenger's seat air mix door actuator opening angle. Useful for reproduction test in faulty events.(1) Ignition switch ON
NOTE: Engine ON is recommended.
Fresh/Rec Air Dr Act Trgt Open Angle -32.68 - 133.33 % Set the intake door actuator opening angle. Useful for reproduction test in faulty events. Ignition switch ON
NOTE: Engine ON is recommended.
Mode Door Actuator Opening Angle Target -32.68 - 133.33 % Set the mode door actuator opening angle. Useful for reproduction test in faulty events. Ignition switch ON
NOTE: Engine ON is recommended.
Blower Fan Level Setting 0 - 255
NOTE: Input up to 255 is possible, but 100 - 255 is the same.
Set the blower fan level. Useful for reproduction test in faulty events. Ignition switch ON
NOTE:
  • Engine ON is recommended.
  • Compressor OFF is needed to set the level to 0.
A/C Change Setting ON/OFF Set the compressor operation request. Useful for reproduction test in faulty events.
  • Engine ON
  • Blower ON
Rear Defogger Setting ON/OFF Transmit the rear defogger switch contact signal. By operating A/C with the signal, it is possible to judge whether the control is faulty or the switch (center information display) is faulty. Ignition switch ON
NOTE: Engine ON is recommended.
Variable Flow Change Solenoid Duty 0 - 100% Set Duty value of variable flow change solenoid valve. Useful for reproduction test in faulty events.
NOTE: The setting value may not be obtained due to A/C circuit protection.
  • Engine ON
  • Compressor ON
  • Blower ON
PTC steps 0 - 3 Set PTC level. Useful for reproduction test in faulty events.(2)
NOTE: The setting value may not be obtained due to power supply circuit protection.
  • Engine ON
  • Blower ON
Heater core temperature setting -40 - 214°C Set the heater core sensor readings. Adjusting the heater core sensor value to use for A/C control is useful for reproduction test in faulty events. Ignition switch ON
NOTE: Engine ON is recommended.
Humidity Setting 0 - 100% Set humidity sensor readings. Adjusting the humidity sensor value to use for A/C control is useful for reproduction test in faulty events.(3) Ignition switch ON
NOTE: Engine ON is recommended.
(1) With left/right independent air conditioning function

(2) With PTC heater

(3) With humidity sensor